The AR 0101 separate shunt increases DC current ratings when connected to a meter with a moving coil. Connection wires with 0.035 Ohm resistance are enclosed with the shunt.

Categories: , .
Description

The AR 0101 separate shunt increases DC current ratings when connected to a meter with a moving coil. Connection wires with 0.035 Ohm resistance are enclosed with the shunt.

imensions comply with DIN 43703. The accuracy class is 0.5.

RATED CURRENT(A)/60mV MASS (kg)
1, 1.5 0,18
2.5, 4, 6, 10,15, 25 0,20
40, 60, 100, 150 0,14
250 0,55
400 0,80
600 0,84
1000 1,50
1500 2
2500 3